Our balloon inflators are compatible with all standard helium cylinders with a hand tight CGA-580 fitting. Brands. The cylinder valve should be positioned so that it is accessible at all times. Examples of CGA fittings would be CGA-580 for Non-flamable, Non-oxidizing gasses such as Nitrogen, Argon, or Helium. 3) General Safety Precautions Of Compressed gas cylinder: Name of the gas and chemical formula shall be mark on the cylinder. All compressed gases are hazardous because of the high pressures inside the cylinders. chain or strap attached 2/3 of the way up on the cylinder. Services include cryogenic repair, telemetry, cylinder re-qualification, and gas cylinder cradle assembly. 800.448.0501. F (21.1 deg. Valve protection for compressed gas cylinders. A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. Key Features & Benefi ts • Automated assembly and testing $33.36. when in storage or use. A gas or mixture of gases having, in a container, an absolute pressure exceeding 40 psi at 70 deg. Compressed Gas Valves We stock a wide range of the top compressed gas valves for you to purchase individually or by the case. 19. They come with a standard rubber tilt valve, and can include built-in ribbon cutter and contents gauge. Standard cylinder-valve outlet connections have been devised by the Compressed Gas Association (CGA) to prevent mixing of incompatible gases. a cylinder or valve. Cylinders secured with a chain or strap must have the . The outlet threads used vary in diameter; some are internal, some are external; some are right-handed, … 2) Hazard Of Compressed gas cylinder: Release of high-pressure gas and flying like rocket if the regulator/safety valve got break. To help prevent serious injury to yourself and others, follow these safe storage practices. The product will be reserved for you when you complete your order. A liquid having a vapor pressure exceeding 40 psi at 100 deg. Compressed Gas Cylinder Safe Handling, Use and Storage September 13, 2017 Safety Resources Page 4 of 29 ... Cylinder valve connections on regulators are also designed to minimize the chances of using the wrong regulator. • Never attempt to repair a cylinder or valve. • Shut the cylinder valve when gas is not in use. Because of the high internal pressure in compressed gas cylinders, they can become projectiles if stored or transported in a manner that could damage the valve. Compressed Gas Cylinder Safety Equipment Suppliers : JTC Valve Sales Gas cylinders may contain gases that are flammable, toxic, corrosive, asphyxiants, or oxidizers. The Compressed Gas Association (CGA) standard can assist in identification of the gas that may be in an unknown cylinder. 100% leak test to 1.2 times cylinder service pressure. (You can also watch the pressure rise on the high-pressure gauge. Customer Service: 888-429-5832 | Local & Outside USA: 630-844-8800. C) regardless of the pressure at 70 deg. Standard Number: 1910.252. Cylinder valves marked with “CGA” plus a 3 digit number correspond with a type of gas or gases that may be in the cylinder: In this example, above the date code is CGA580. Removing the valve ensures no material is left in the cylinder. CGA 510; 3/414 NGT; No PRD - GV51060. 17. Inspection for damaged or faulty cylinder with regulators and valve. Compressed Gas Cylinders Page 3 of 3 All cylinder movement should be done Always secure the cylinders . F (54.4 deg. It is obviously the most vulnerable part of a compressed gas package. We manufacture world-class cylinder caps, valve protection, couplings, thread protectors, and compressed gas components. Our valves are precision made with high-quality materials and components meeting tight Compressed Gas Association (CGA) specifications. All marking on the valve neck, protects against damage. Many compressed gas cylinders are stored at extremely high pressures (up to 2,500 pounds per square inch gauge or PSIG). Once the cylinder pressure decreases to the valve’s pressure setting, the valve will normally reseat without leakage. 3/8-18 NGT CBI 5 200 3 Acetylene 200 .625-20 NGO RH Ext. Add to Cart. ACETYLENE VALVES Helium Balloon Fillers and Inflators are one of Compressed Gave Valve’s featured products. Leaking cylinders may displace air, causing an oxygen-deficient atmosphere that can lead to unconsciousness or death. CGA V-1 Compressed Gas Cylinder Valve Outlet and Inlet Connections CGAV9 Standard for Gas Cylinder valves Torque Values for PBH/PBI Acetylene valves Ordering Information Part Number Gas Service CGA Outlet Outlet Thread Size Inlet Thread Size CBH 5 520 3 Acetylene 520 .895-18 NGO RH Ext. Its function is very critical as the compressed gases contained within them are subjected to explosion if any mishandling is caused. 18. Note: Product availability is real-time basis and adjusted continuously. Add to Compare. Cylinder Devalving Tool. SHERWOOD VALVE COMPRESSED GAS PRODUCTS Industrial Gas Valves GV & GVHM Series Global Industrial Gas Valves Designed for use in every country around the world. According to OSHA Hazard Communication Standard: “Compressed gas” means: 1. Are all compressed gas cylinders subjected to periodic hydrostatic testing and interior inspection by suppliers? Compressed Gas Cylinder Valve Protector. Compressed gas cylinders should be stored – upright and secured with sturdy restraints – in dry, well-ventilated areas, with their contents (and hazard class) clearly marked. For use in cylinders containing oxygen, argon, carbon dioxide, nitrogen, helium and hydrogen, as well as welding gas mixtures. Compressed gases are commonly used in laboratories. Valves are available from small to large cylinders up to 6000PSI service pressure. Standard Interpretations. This video shows what can happen when cylinder vales are Dropped, Broken etc and are opened or closed as needed during filling operations or for the withdrawal of product from Standard Interpretations. Add to Wishlist. A gas or mixture of gases having, in a container, an absolute pressure exceeding 104 psi at 130 deg. OSHA requirements are set by statute, standards and regulations. These tools help to remove valves from gas cylinders before proper disposal or recycling. Compressed Gas Cylinder Valves for Various Gases, Aluminum and Steel Cylinders. • Firmly attach cylinders to a bench top, wall, or holding cage. E. Limit inside storage areas for fuel gas to a total gas capacity of 2,000 cubic feet (about 13 large cylinders). Standard cylinder-valve outlet connections have been devised by the Compressed Gas Association (CGA) to prevent mixing of incompatible gases. Are safety relief devices in the valve or on the cylinder free from any indication of tampering? Standard Number: 1910.253 (b) (1) (iv) OSHA requirements are set by statute, standards and regulations. Cylinder Valves Cylinder valves allow gases to be filled into or emptied from a cylinder. Cylinder Valves • Have Compressed Gas Association (CGA) standard outlet ports. Gas can be released deliberately by opening the cylinder valve, or accidentally from a broken or leaking valve or from a safety device. Even at a relatively low pressure, gas can flow rapidly from an open or leaking cylinder. 3/8-18 NGT Ever wondered what happens to a medical gas cylinder if the regulator gets snapped off? •After the regulator is attached, the cylinder valve should be slowly opened just enough to indicate pressure on the regulator gauge (no more than one full turn), and all the connections checked with a soap solution for leaks. CNG cylinder inspection labels are applied to CNG cylinders to demonstrate the "Pass" or "Fail" result of a detailed CNG cylinder inspection. These inspections are required by the National Highway Transportation Safety Administration's (NHTSA) FMVSS 304 which states that a detailed visual inspection of all CNG cylinders must be conducted by qualified CNG fuel system inspectors every three years or 36,000 miles (whichever comes first) and after any fire or accident. Unsecured cylinders can be easily knocked over, causing serious injury and damage. PTR Group custom manufactures metal components and subassemblies and is a leading supplier of high-precision thermoplastic injection mold tooling, zinc die-cast mold tooling, and molded plastic components. Cylinder Valves for Industrial Gases. – When opened completely, the valve seals off its own packing box. Evergreen Provides a wide variety of valves as Compressed Gas Cylinder Valves, Cryogenic Valves, Diaphragm Valves, Industrial valve & Valves accessories Made in the USA to meet the safety levels. Compressed gases present a number of hazards for the laboratory worker. Our interpretation letters explain these requirements and how they apply to particular circumstances, but they cannot create additional employer obligations. Gas identification is typically stamped or stenciled onto the cylinder – or on a label affixed (or otherwise attached) to the cylinder. Purchased products. F (21.1 deg. This type of device is most commonly found with medical-grade gas cylinders. Use chains or sturdy straps. Safe handling of these cylinders is required for all concerned. O-Ring technology provides superior leak integrity. with a compressed gas cylinder cart. Compressed Gas Cylinder Safety Precautions. Open the valve handle on the compressed gas cylinder S-L-O-W-L-Y, until you hear the space between the cylinder valve gently fill the gas. Compressed Gas Valves. • Cylinder valve is an ON/OFF switch: open or close completely. Impact can shear the valve from an uncapped cylinder, causing a Always verify that you have the correct regulator for your application. … Well here it is! – The cylinder valve is NOT used to regulate gas flow or pressure. Never rely on the color of the cylinder for identification. • Compressed Gas Assocation(CGA) number on valve tells you a lot • CGA plus 3 digits –e.g., CGA 540 • Number identifies shape and thread of inlet and outlet connections –where you attach to valve • Indicates what gases might be inside • Will sometimes tell you exact gas • Will indicate characteristics: corrosive, flammable, inert, etc. F. Mark compressed gas cylinders legibly, for the purpose of identifying the gas content, with either the chemical or the trade name of the gas… Compressed gas cylinders are used in a variety of applications involved with ambient air monitoring. Are all compressed gas cylinders regularly inspected for corrosion, pitting, cuts, gouges, digs, bulges, neck defects Our interpretation letters explain these requirements and how they apply to particular circumstances, but they cannot create additional employer obligations. D. Do not place gas cylinders within 6 feet of an electrical source. compressed gases, especially when connecting and disconnecting compressed gas regulators and lines. All compressed gases are hazardous because of the high pressures inside the cylinders. Gas can be released deliberately by opening the cylinder valve, or accidentally from a broken or leaking valve or from a safety device. Even at a relatively low pressure, gas can flow rapidly from an open or leaking cylinder. This valve allows the cylinder to contain gases and allows gas to be filled into or emptied from the cylinder. Cyl-Tec supplies high quality compressed gas cylinders, cryogenic bulk tanks, BevCarb liquid cylinders, valves, and related accessories. The outlet threads used vary in diameter; some are internal, some are external; some are right-handed, some are left-handed. As you might expect compressed air is the cheapest of the gases that are used in welding because it's air. (Though it is often purified a little). When you mix compressed air with another fuel then it can produce a strong flame at a lower temperate than an oxy-fueled flame. A sudden release of these gases can cause a cylinder to become a missile-like projectile capable of penetrating a concrete block wall. The cylinder valve is the most vulnerable part of the compressed gas package and requires a thorough understanding to maximize its performance. ProRack Gas Control Products stocks a large inventory of compressed gas cylinder valves for Acetylene, Inert, Oxygen, Breathing Air and Hydrogen to name a few. C); or 2. Open the valves from side. Always ensure the cylinder is set to the correct pressure indicated for that gas. Sherwood Valve manufactures valves and accessories for all segments of the compressed gas market including industrial gases, acetylene, medical, refrigerant recovery, mining, oxygen, propylene, alternative energy and more. • Pressure Relief Valves: A spring-loaded valve opens when the cylinder pressure exceeds the pressure setting of the spring to discharge contents. Always point the valve and opening away from the body and away from anyone else in case there is a failure to the regulator, which may cause the valve stem on the regulator to fail and blow out. Instead of using a method that makes dropping or striking likely, OSHA gas cylinder transportation regulations require workers to move gas cylinders by rolling them along their edges. When workers move cylinders by hoisting them, they should be securely attached to a cradle, slingboard or pallet. Shop Now. Available bursting discs for all DOT cylinders… Gas cylinders must be clearly identified. C); or 3. CGA-590 is used for compressed air and CGA-326 is used for Nitrous Oxide. Large seat orifice provides faster vacuum and filling rates.